AUTOMATIC CONTROL
PANELS
Automatic control module provides integrated generator set
control, protection, metering and automatic load transfer. If a fault is
detected, the engine will automatically shutdown and the failure will be
indicated by the LCD display and alarm horn. The unit detects failure of any
phase in the mains supply and is able to start the generator and transfer the
load. When the mains supply is restored within the pre-set limits, the load is
transferred back to the mians supply and the generator is shutdown in a
controlled manner. The unit offers manuel, fully automatic and test mode which
allows the generator to be run without taking the load. Mode of the operation
can be changed at any time without affecting the operation status of the
generator or load connection

CONTROLLER
FEATURES
• Protection, control and metering • Automatic engine
start/stop and load transfer • Automatic shutdown on fault condition • LED
status and fault indication • Simple push button controlled operation •
Manuel, automatic and test mode control • Six user inputs configurable •
Three resistive sender inputs • Four user outputs configurable • Speed
sensing from alternator voltage or magnetic pick up • Exercise at programmed
time intervals • Maintenance warning • Fully programmable • RS 232
communication port • Modbus-RTU protocol
|
 |
BASIC INSTRUMENTATION
•
Engine Speed • Engine Oil pressure • Coolant temperature • Battery
voltage • Charge alternator voltage • Engine run time • Next
maintenance (if enabled) • Generator volts (L1-N, L2-N, L3-N) • Generator
volts (L1-L2, L2-L3, L3-L1) • Generator Hz • Generator Amps (L1, L2,
L3) • Generator earth current • Generator kW • Generator kVA •
Generator pf • Generator kVAr • Generator kWh/Generator kVAh/Generator
kVArh • Mains volts (L1-N, L2-N, L3-N) • Mains volts (L1-L2, L2-L3,
L3-L1) • Real time • Error messages • Event logs • Program
parameters
PROTECTIONS
• Emergency
stop • Failed to start • Low oil pressure • High engine
temperature • Over / under speed failure • Voltage failure • Charging
failure • Over current • Short circuit • Low water level failure •
Maintenance failure
CONTROL MODULE CONFIGURATION
WITH SOFTWARE
The control modules configuration software allows
the modules to be connected to a PC.
Once connected the various
operating parameters within the module can be viewed or edited as required by
the engineer. This software allows easy controlled access to these values and
also has diagnostic monitoring facilities.

The Configuration interface should only be used by competent,
qualified personnel, as changes to the operation of the module may have safety
implications on the panel / generating set to which it is fitted. Access to
critical operational sequences and settings for use by qualified engineers, are
barred by a PC software security code. Timers are protected by a separate code
allowing operator changes to be made.
The information contained in
this manual should be read in conjunction with the information contained in the
appropriate module documentation. The operation of the module is detailed in its
own relevant manual.
For legacy support, an RS232 version is also
available with an adapter cable to allow connection to the 9 pin D type RS232
connectors as required.

MANUEL CONTROL
PANELS
Manuel control panel includes: • 1 unit
Voltmeter • 1 unit Ampermeter • 1 unit Frequencymeter • 1 unit
Voltmeter commutator • 1 unit Ampermeter commutator • 1 unit Emergency
stop button • 1 unit Operation hourmeter • 1 unit Oil pressure gauge •
1 unit Water temperature gauge • 1 unit Start switch • 1 unit Manuel
selection switch • 3 units Indicator (charge, oil,
temperature)
|
 |
|